Camel Heat Load Calculation Software
May 20, 2011 - Does anyone know of a good heat load calculation program online for. Camel software at Free download!
QwickLoad uses the ASHRAE TFM (Transfer Function Method) algorithms combined with a screen interface that provides building load calculations. It includes a Duct Sizing Program and supports IP and SI units. QwickLoad Residential 7.0 provides heat gain and heat loss calculations for up to 10 zones. QwickLoad Commercial 7.0 provides heat gain and heat loss calculations for up to 500 zones.
Zones and plenums can be added or deleted with one button click. Intuitive screens for entering building information. Default is automatically displayed. Construction types for roofs, walls, partitions, windows, shade types, and scheduling control. Complete air-conditioning and heating system control and supply, return, heating and cooling duct static pressure specification.
Energy recovery ventilator can be added. Full-color PDF user manual is bookmarked throughout. Error check message dialogs describe errors and include corrective action.
Includes load check for individual zones. Built-in automatic outside air summer and winter design temperatures enables user to view the building load as zones or components are added. Load calculation enables user to review the building load and see errors or missing data.
Heat load calculations – heat gain for air conditioner sizing Cooling Heat load calculations spacer Search this site: Using: All Words Any Words Phrase W. Tombling Ltd. Wembley House Dozens Bank West Pinchbeck Spalding Lincolnshire PE11 3ND U.K. Telephone +44 (0) 1775 640 049 Facsimile +44 (0) 1775 640 050 Email You are here:- > > > determining the size of air conditioner required Heat load or heat gain A building or room gains heat from many sources.
Inside occupants, computers, copiers, machinery, and lighting all produce heat. Warm air from outside enters through open doors and windows, or as ‘leakage’ though the structure. However the biggest source of heat is solar radiation from the sun, beating down on the roof and walls, and pouring through the windows, heating internal surfaces. The sum of all these heat sources is know as the heat gain (or heat load) of the building, and is expressed either in BTU (British Thermal Units) or Kw (Kilowatts).
Twilight render v1 4 5 cracked. For an air conditioner to cool a room or building its output must be greater than the heat gain. It is important before purchasing an air conditioner that a heat load calculation is performed to ensure it is big enough for the intended application. Heat load calculations There are several different methods of calculating the heat load for a given area: Quick calculation for offices For offices with average insulation and lighting, 2/3 occupants and 3/4 personal computers and a photocopier, the following calculations will suffice: Heat load (BTU) = Length (ft.) x Width (ft.) x Height (ft.) x 4 Heat load (BTU) = Length (m) x Width (m) x Height (m) x 141 For every additional occupant add 500 BTU. If there are any additional significant sources of heat, for instance floor to ceiling south facing windows, or equipment that produces lots of heat, the above method will underestimate the heat load. In which case the following method should be used instead. A more accurate heat load calculation for any type of room or building The heat gain of a room or building depends on: The size of the area being cooled The size and position of windows, and whether they have shading The number of occupants Heat generated by equipment and machinery Heat generated by lighting By calculating the heat gain from each individual item and adding them together, an accurate heat load figure can be determined.
Step One Calculate the area in square feet of the space to be cooled, and multiply by 31.25 Area BTU = length (ft.) x width (ft.) x 31.25 Step Two Calculate the heat gain through the windows. If the windows don’t have shading multiply the result by 1.4 North window BTU = Area of North facing windows (m. Sq.) x 164 If no shading, North window BTU = North window BTU x 1.4 South window BTU = Area of South facing windows (m. Sq.) x 868 If no shading, South window BTU = South window BTU x 1.4 Add the results together. Total window BTU = North window + South window Step Three Calculate the heat generated by occupants, allow 600 BTU per person. Occupant BTU = number of people x 600 Step Four Calculate the heat generated by each item of machinery - copiers, computers, ovens etc. Find the power in watts for each item, add them together and multiply by 3.4 Equipment BTU = total equipment watts x 3.4 Step Five Calculate the heat generated by lighting.